Background
Neilcott Construction undertook the redevelopment of Beormund SEMH Primary School in Peckham, London. The project involved demolishing the existing school and constructing a new, part-single, part-two storey Special Educational Needs (SEN) primary school, including a community changing room, MUGA, landscaping, and associated facilities.
The school’s user base comprises pupils with Social, Emotional, and Mental Health (SEMH) needs, requiring an environment that is both inclusive and acoustically calming.
Challenge
The primary challenges were:
- Acoustic Sensitivity: Pupils with SEMH, autism, and related needs are highly sensitive to noise. Excessive noise or reverberation can trigger anxiety and impact learning and wellbeing;
- Regulatory Compliance: The design needed to meet or exceed stringent standards, including Building Bulletin 93 (BB93), BREEAM Hea 05 and Pol 05 credits, and the Equality Act 2010;
- Complex Site Context: The school is located in a residential area, adjacent to noise-sensitive receptors, and within an Air Quality Management Area (AQMA);
- Indoor Air Quality: Ensuring excellent indoor air quality (IAQ) for vulnerable users, in line with BREEAM and legislative requirements, while using only electric heating and ventilation systems.
What We Did
Acoustic Design
- Evidence-Based Acoustic Strategy: Developed a comprehensive acoustic strategy at both Stage 3 and Stage 4, tailored to the specific needs of SEMH pupils. This included:
-
- Enhanced Sound Insulation: Specified robust wall, floor, and ceiling constructions to achieve or exceed BB93 standards for airborne and impact sound insulation. Where simultaneous use of adjacent spaces was unlikely, alternative performance standards were justified and agreed with stakeholders;
- Reverberation Control: Proposed a mid-frequency reverberation time (Tmf) of 0.5 seconds for teaching and therapy spaces, based on research for the Department for Education and in consultation with the client’s representatives. This is more stringent than standard requirements, supporting the needs of aurally diverse learners;
- Mechanical Ventilation: Proposed a full mechanical ventilation system (MVHR) to avoid reliance on open windows, thus maintaining acoustic integrity and preventing external noise ingress;
- Mitigation of Plant Noise: Used advanced modelling (CadnaA, ISO 9613-2) to predict plant noise at sensitive receptors. Where initial predictions exceeded criteria, implemented mitigation measures such as acoustic screens, attenuators, and full enclosures for rooftop plant;
- Assistive Listening: Proposed integrated hearing loops and ensured compliance with the Equality Act for accessible learning environments.
Indoor Air Quality
- BREEAM-Compliant IAQ Plan: Developed an Indoor Air Quality Plan in line with BREEAM UK New Construction 2018, covering:
-
- All-Electric Heating & Cooling: Eliminated combustion-based systems, using VRF units and heat pumps to avoid NOx and particulate emissions;
- Low-Emission Materials: Specified low-VOC paints, adhesives, and finishes, with rigorous compliance checks;
- Ventilation & Filtration: Proposed mechanical ventilation with heat recovery and, where required, filtration to manage CO₂ and particulates;
- Construction Controls: Advised best practices during construction to minimize dust and VOCs, including pre-occupancy flush-out and third-party IAQ testing.
- Ongoing Maintenance: Provided user guidance for maintaining IAQ, including regular cleaning, filter replacement, and monitoring.
Result
- Acoustic Excellence: The final design achieves or exceeds all relevant acoustic standards, providing a calm, inclusive environment tailored to SEMH pupils. Enhanced sound insulation, reverberation control, and plant noise mitigation ensure both regulatory compliance and user comfort;
- BREEAM & Regulatory Compliance: The project is on track to achieve BREEAM “Excellent” rating, with all targeted Hea 05 and Pol 05 credits supported by robust evidence and pre-completion testing;
- Healthy Indoor Environment: The all-electric, low-emission design, combined with rigorous IAQ management, ensures a safe, healthy environment for pupils and staff, with pollutant levels well below statutory and WHO thresholds.






Images credit @ Robby Whitfield, Central Photography and Neilcott Construction Ltd