Background
Anderson Acoustics was appointed to assess groundborne vibration and re‑radiated noise from the proposed Crossrail 2 tunnels in support of a residential redevelopment at 82–84 Kingsland High Street, Dalston.
The assessment was undertaken to discharge a planning condition and demonstrate compliance with Crossrail 2 safeguarding requirements.
The Challenge
The site is located within the Crossrail 2 safeguarding limits, with the tunnel alignment positioned immediately adjacent to the eastern site boundary. The proposals involved new residential apartments constructed above a retained ground‑floor retail unit, creating a sensitive acoustic environment.
The key challenge was to demonstrate that operational vibration and re‑radiated noise from future Crossrail 2 services would not adversely affect internal residential conditions, using an assessment approach acceptable to both the Local Planning Authority and Crossrail 2 consultees.
Our Approach
A detailed vibration and re‑radiated noise assessment was completed in accordance with the Crossrail 2 Tunnel Section Information for Developers (April 2021). The methodology focused on predicting vibration transmission from subterranean train pass‑bys through the ground and into the building structure.
The assessment combined Crossrail 2 reference vibration data with site‑specific geological information, tunnel geometry and foundation details provided by the project structural engineer.
Vibration levels were derived using reference data representative of train movements in proximity to the proposed Dalston station, where train speeds are expected to be reduced. Ground propagation losses were calculated using London Clay parameters informed by borehole investigation data.
Building response was assessed conservatively, incorporating reinforced concrete raft and ribbed slab foundations with high amplification assumptions in line with ANC guidance. Re‑radiated noise levels were assessed within the nearest first floor apartment, representing the worst‑case residential receptor.
The Outcome
The predicted maximum re‑radiated noise level was 32 dB LAmax,fast, achieving the Crossrail 2 residential criterion of 35 dB LAmax,fast with a 3 dB margin. This result was achieved despite the use of intentionally conservative assumptions throughout the assessment.
Given the compliant re‑radiated noise predictions, operational tactile vibration levels were also considered likely to remain within relevant guidance limits. No additional vibration mitigation or enhanced soundproofing measures were required to support the proposed development.
Conclusion
This assessment provided robust, evidence‑based support for residential development adjacent to safeguarded rail infrastructure. By applying recognised guidance, conservative modelling assumptions and site‑specific design information, we demonstrated that acceptable internal noise and vibration conditions can be achieved for future residents.
Project Progress
Hackney Borough Council discharged planning condition 7 related to Noise and Vibration on 21st April 2026.